Click HereModular Cleanroom Maintenance Checklist-Free Printable Templates & ISO Compliance
Table of Contents
Core Maintenance Checklists
Our comprehensive Modular Cleanroom Maintenance Checklist system is organized by frequency to ensure all critical components receive appropriate attention. Each task includes specific acceptance criteria and responsible personnel assignments to maintain accountability.
Following a structured Modular Cleanroom Maintenance Checklist reduces particle counts by 35-60% compared to ad-hoc maintenance approaches, according to Deiiang™ performance data. The checklists below represent industry best practices developed by cleanroom experts including Jason.peng.

Modular Cleanroom Maintenance Checklist
Daily Maintenance Checklist
| Task | Frequency | Responsible | Acceptance Criteria | Notes |
|---|---|---|---|---|
| Floor and wall cleaning | Daily | Cleanroom Operator | No visible particles, smudges or stains | Use approved cleaners only |
| HEPA filter visual inspection | Daily | Supervisor | No visible damage or excessive loading | Document any abnormalities |
| Differential pressure check | Daily | Technician | 10-15 Pa between adjacent zones | Record in pressure log |
| Gowning area cleaning | Daily | Cleanroom Operator | No contamination sources present | Check gown integrity |
Weekly Maintenance Checklist
| Task | Frequency | Responsible | Acceptance Criteria | Notes |
|---|---|---|---|---|
| Particle count sampling | Weekly | QA Technician | Within ISO class limits | Minimum 5 locations |
| Surface disinfecting verification | Weekly | Microbiology | Contact plates < action limit | Rotate locations weekly |
| Waste handling inspection | Weekly | Supervisor | Proper segregation and removal | Check disposal records |
Monthly Maintenance Checklist
| Task | Frequency | Responsible | Acceptance Criteria | Notes |
|---|---|---|---|---|
| Airflow & ACH verification | Monthly | HVAC Technician | ±10% of design specification | Record velocity readings |
| HEPA filter integrity testing | Monthly | Validation Team | No leaks > 0.01% | Photometer scan method |
| Pressure transducer calibration check | Monthly | Metrology | ±1% of reference standard | Document deviations |
Quarterly Maintenance Checklist
| Task | Frequency | Responsible | Acceptance Criteria | Notes |
|---|---|---|---|---|
| Comprehensive particle counting | Quarterly | QA/Validation | Full ISO 14644-1 compliance | Minimum sample locations formula: √A |
| Air change rate verification | Quarterly | HVAC Engineer | Meet classification requirements | ISO Class 5: 240-600 ACH typical |
| Temperature/humidity mapping | Quarterly | Validation Team | Within specified ranges | 9-point minimum mapping |
Annual Maintenance Checklist
| Task | Frequency | Responsible | Acceptance Criteria | Notes |
|---|---|---|---|---|
| Full HEPA/ULPA filter replacement | Annual | HVAC Specialist | 99.99% efficiency at 0.3μm | Based on pressure drop & age |
| Complete requalification testing | Annual | Validation Team | All ISO 14644 tests passed | Full documentation required |
| Structural integrity inspection | Annual | Facilities Engineer | No cracks, gaps or seal failures | Check panel joints & seals |
Equipment & Systems Specialized Checklists
The equipment-specific Modular Cleanroom Maintenance Checklist components ensure critical systems maintain optimal performance. HVAC systems typically account for 55-65% of cleanroom energy consumption, making proper maintenance essential for both performance and efficiency.
Deiiang™ modular cleanrooms incorporate specialized monitoring systems that integrate with these maintenance protocols. Our design approach, led by product designer Jason.peng, emphasizes serviceability to reduce maintenance downtime by up to 40% compared to traditional cleanrooms.
HVAC & Air Handling Units
- Filter replacement scheduling based on pressure drop
- Airflow balancing and velocity verification
- Fan coil unit inspection and cleaning
- Ductwork integrity checks
HEPA/ULPA Filter Testing
- Integrity testing (DOP/PAO challenge)
- Pressure drop monitoring
- Replacement criteria: 1.5-2x initial pressure drop
- Visual inspection for damage
Pressure Cascade Monitoring
- Differential pressure verification
- Alarm setpoint validation
- Room pressure relationship mapping
- Door interlock functionality testing
Validation & Documentation Requirements
Proper documentation is essential for regulatory compliance and quality assurance. A well-maintained Modular Cleanroom Maintenance Checklist system includes comprehensive record-keeping that withstands regulatory scrutiny.
Our validation approach for the Modular Cleanroom Maintenance Checklist includes electronic record systems with audit trails, reducing documentation errors by 72% according to Deiiang™ client data. Records should be maintained for a minimum of 3-7 years depending on product lifecycle and regulatory requirements.
Recommended Documentation Practices
Record Retention
- Maintenance logs: 3 years minimum
- Validation protocols: Product lifecycle + 1 year
- Filter certifications: Until replacement
- Calibration records: 3-7 years
Electronic vs Paper
- Electronic: 21 CFR Part 11 compliance
- Paper: Controlled forms with unique numbering
- Hybrid: Electronic master with paper backups
- Cloud storage with regular backups
Compliance & Standards Alignment
Our Modular Cleanroom Maintenance Checklist is designed to meet major international standards and regulatory requirements. The checklist incorporates specific requirements from ISO 14644, EU GMP, and FDA guidance documents.
Implementing a standardized Modular Cleanroom Maintenance Checklist ensures consistent compliance across multiple facilities. Deiiang™ clients report 95% first-pass success rates during regulatory inspections when following our comprehensive maintenance system developed by experts including Jason.peng.
| Standard | Requirements | Checklist Alignment |
|---|---|---|
| ISO 14644-1 | Particle counting, classification | Monthly/quarterly particle monitoring |
| ISO 14644-2 | Monitoring for continued compliance | Continuous pressure & periodic testing |
| EU GMP Annex 1 | Microbial monitoring, aseptic processing | Weekly surface & air microbial monitoring |
| FDA Aseptic Guide | Environmental monitoring program | Comprehensive EM with action limits |
Frequently Asked Questions & Troubleshooting
This section addresses common challenges in modular cleanroom maintenance and provides practical solutions. A well-implemented Modular Cleanroom Maintenance Checklist should include contingency procedures for typical operational issues.
The troubleshooting guidance in our Modular Cleanroom Maintenance Checklist has helped Deiiang™ clients reduce cleanroom downtime by an average of 45% through rapid problem identification and resolution.
How to address pressure differential fluctuations?
Immediate actions:
- Check for open doors or pass-throughs
- Verify HVAC system operation
- Inspect pressure sensor calibration
- Check filter loading status
When to escalate: Fluctuations persisting >15 minutes or exceeding ±25% of setpoint require immediate QA notification and investigation.
How to respond to particle count excursions?
Immediate actions:
- Verify sampling procedure compliance
- Check personnel activities and count
- Review recent maintenance activities
- Inspect filter integrity
When to escalate: Any excursion beyond action limits requires immediate process suspension, QA notification, and formal investigation.
How to manage microbial contamination events?
Immediate actions:
- Enhanced cleaning with sporicidal agents
- Review gowning procedures and compliance
- Check material transfer procedures
- Verify disinfectant efficacy and rotation
When to escalate: Repeated positive samples or multiple locations positive require full investigation, media fills, and possible shutdown.
Download Complete Checklist Templates
Access our professionally designed, ready-to-use checklist templates in multiple formats. All templates include built-in compliance features and are regularly updated to reflect current regulatory requirements.
All templates developed by Deiiang™ cleanroom experts including product designer Jason.peng. Last updated: March 2024