Handheld Particle Counter

Deiiang builds eleven handheld particle counters from 0.1 to 28.3 L/min on one optical platform, each shipped with an ISO 21501-4 calibration certificate, an on-board ISO class verdict and records that hold up in audit.

/uploads/allimg/20261018/1-26101Q51644Y6.webp

Need a handheld particle counter solution?

Our professional team will provide you with customized handheld particle counter solutions to meet your specific needs.

Types Of Deiiang Handheld Particle Counters

Eleven handheld models share one optical platform, so the choice comes down to sample volume and what the record has to prove: 0.1 L/min for isolators and glove ports, 2.83 L/min for point checks and monitoring rounds, 28.3 L/min when a room has to be classified, and printed or camera-backed evidence where an auditor signs the sheet.
Deiiang Handheld Dust and Particle Monitor
Handheld Dust & Particle Monitor
0.3 L/min PM2.5 and PM10 screening, plus temperature and humidity, in one hand.
Send inquiry Now
Deiiang Micro-Flow Handheld Particle Counter
Micro-Flow Handheld Particle Counter
0.1 L/min for isolators and glove ports where a full sample would disturb the zone.
Send inquiry Now
Deiiang Handheld Airborne Particle Counter
Handheld Airborne Particle Counter
2.83 L/min, six channels, ISO class on screen. The counter most sites carry.
Send inquiry Now
Deiiang Handheld Particle Counter with Pump
Handheld Particle Counter with Pump
Piston pump pulls 2.83 L/min through two metres of tube for ducts and filters.
Send inquiry Now
Deiiang Handheld Particle Counter with Printer
Handheld Particle Counter with Printer
Built-in thermal printer, signed record at the sampling point, 4.3 inch display.
Send inquiry Now
Deiiang High-Capacity Handheld Particle Counter
High-Capacity Handheld Particle Counter
One million records, a year of daily rounds without downloading. 2.83 L/min.
Send inquiry Now
Deiiang Touchscreen Handheld Particle Counter
Touchscreen Handheld Particle Counter
3.5 inch glove-friendly touchscreen, count and mass modes in a single tap.
Send inquiry Now
Deiiang Precision Handheld Particle Counter
Precision Handheld Particle Counter
Reference optics with per-channel calibration and 95 percent UCL on screen.
Send inquiry Now
Deiiang Particle Counter with Camera and Environment
Particle Counter with Camera & Environment
Adds a camera and climate sensors to every record, photo evidence for deviations.
Send inquiry Now
Deiiang Five-in-One Particle and Gas Meter
Five-in-One Particle & Gas Meter
Particle count plus HCHO and CO on one probe for handover and air complaints.
Send inquiry Now
Deiiang Large-Flow Handheld Particle Counter
Large-Flow Handheld Particle Counter
28.3 L/min in the hand: one cubic foot a minute, an ISO sample inside a minute.
Send inquiry Now

Product Feature

ABOUT

Learn More About Deiiang Handheld Particle Counter

Aerial view of Deiiang Company

Deiiang Handheld Particle Counter Quality Control Flowchart

Technical Resources

Total 0 resources

Micro-flow 0.1 L/min handheld vs. standard 2.83 L/min handheld particle counter

Micro-flow 0.1 L/min handheld particle counter

Micro-flow 0.1 L/min handheld
VS

Standard 2.83 L/min handheld particle counter

Standard 2.83 L/min handheld

Micro-flow 0.1 L/min handheld

The micro-flow unit moves a tenth of a litre a minute, which at first sounds like a drawback and in the right place is the whole point. Sampling inside an isolator or through a glove port barely disturbs the air you are trying to measure, and the low inlet velocity keeps isokinetic error small at short range. The trade is time: a hundred litres takes about seventeen hours, which is why it is used for spot checks and trend work rather than formal classification.

Standard 2.83 L/min handheld

2.83 L/min is the volume most handhelds are built around, and it gives a usable reading in a few minutes with six size channels and an ISO class verdict on the same screen. Point checks, monitoring rounds and certification support all work at this flow, and the record carries location tags. For a Grade A zone where the probe has to sit next to open product, that extra air movement is what you have to justify.

Industry Applications

Deiiang handheld particle counter in Pharmaceutical and Biologics

Pharmaceutical & Biologics

Annex 1 rounds mean the probe goes where the product is. A handheld gets into the filling zone without moving a trolley through a Grade A airlock.

Send inquiry Now
Deiiang handheld particle counter in Semiconductors and Electronics

Semiconductors & Electronics

Fab budgets are tight and drift shows in yield first. Handheld counters check a tool enclosure after maintenance, before wafers go back in.

Send inquiry Now
Deiiang handheld particle counter in Hospitals and Operating Rooms

Hospitals & Operating Rooms

Theatre air is verified between cases, not during one. A handheld classifies the room at the diffuser and logs the reading for infection control.

Send inquiry Now
Deiiang handheld particle counter in Medical Devices and Diagnostics

Medical Devices & Diagnostics

Sterile assembly rooms need a record per shift. A handheld with a printer signs at the bench, so nothing is retyped into the batch file.

Send inquiry Now
Deiiang handheld particle counter in Food and Beverage Processing

Food & Beverage Processing

Aseptic fillers are rechecked after CIP, often inside a narrow window. A handheld with a pump samples through tubing without opening the enclosure.

Send inquiry Now
Deiiang handheld particle counter in Aerospace and Precision Assembly

Aerospace & Precision Assembly

Optics and satellite parts travel with their cleanliness evidence. A handheld survey prints a page that goes into the build pack with the hardware.

Send inquiry Now

How to Work With Us

Upload requirements

Upload requirements

Submit your product requirements, including specifications, parameters, quantity, certification requirements, etc.

Confirm requirements and provide a quote

Confirm requirements and provide a quote

We will confirm your detailed requirements within a few hours and develop a preliminary design based on them.

Confirm Quote

Manufacturing Begins

Once you review your quote and place your order, we'll start the manufacturing process. We also offer finishing options.

Parts are Shipped

Parts are Shipped!

Our digital manufacturing process allows us to produce parts in as fast as 1 day.

Customer feedback reflects our value—take a look at what our customers say about our products and services.

Bought the H200 for our filling hall. Two minutes a point, class shown on the screen, and the slip goes into the file. Nothing more to say, it does the job.

Andreas Keller

The H100 is the only thing we found that samples a glove port without pushing air around. Slow, yes, but that is the trade.

Priya Raghavan

Dropped mine on a steel floor in week two. Cracked the case, kept counting. Calibration held, which surprised me more than the drop.

Tom Whitfield

We run 40 points a week across three sites. The H230 has not been downloaded in months, the buffer just keeps taking it.

Magdalena Wójcik

Printer on the H220 is a bit loud in a quiet suite, but the auditor liked getting a signed sheet on the spot.

Jean-Luc Bertrand

Took the H300 for Grade B classification. One minute a point instead of five changed how we plan the shutdown.

Hiroshi Nakamura
Frequently Asked Questions (FAQ)
What is a handheld particle counter used for?

Point checks and monitoring rounds: a technician carries it to the sampling location, draws a known volume of air and reads the count against the class limit. It is also used for filter leak surveys, compressed gas testing and spot checks inside isolators.

Which flow rate should I choose, 0.1, 2.83 or 28.3 L/min?

0.1 L/min is for places where moving a lot of air would disturb the zone, such as glove ports. 2.83 L/min is the everyday choice for point checks and rounds. 28.3 L/min samples one cubic foot per minute, which makes ISO 14644-1 classification practical.

Can a handheld counter be used for ISO 14644-1 certification?

Yes, provided the sample volume and the number of points meet the standard and the instrument holds a current ISO 21501-4 calibration certificate. At 2.83 L/min each point takes about 21 minutes, so most certification work is done with the 28.3 L/min model.

How often does it need calibration?

Once a year is the normal interval, against polystyrene latex spheres and traceable to a national standard. If the unit is dropped or the flow looks wrong, send it in early rather than waiting for the anniversary.

What is the difference between the models with a printer and with a camera?

A printer produces a signed sheet at the sampling point, which suits GMP batch records. A camera stores a photo with each reading, which is more useful in deviation reports where you need to show what the area looked like at the time.

How long does the battery last during a survey?

Around six hours at full flow on the 28.3 L/min model and longer at 2.83 L/min. Cold rooms and full-flow classification shorten that, so plan a charge between buildings or carry a second pack.

How to choose Handheld Particle Counter?

1

Start With The Flow Rate

A 2.83 L/min handheld covers point checks and monitoring rounds. Go to 0.1 L/min near open product or inside an isolator, and to 28.3 L/min when a room has to be classified.

2

Check The Smallest Channel

Six channels from 0.3 μm is the useful minimum. If you work to a specification that counts 0.2 μm, confirm the optics actually resolve it rather than interpolating.

3

Decide What The Record Must Prove

A screen reading is not evidence. Ask whether you need a printed slip, an audit trail with operator ID, or a photo attached to the reading.

4

Battery And Weight

A full round can run to four hours. Check the quoted life at full flow, and hold the unit for a minute before buying: 1.6 kg feels different at shoulder height.

5

Display And Gloves

Operators wear nitrile or sterile gloves. A resistive screen will not respond to them, so test the touchscreen the way your team will use it.

6

Calibration And Certificate

Insist on an ISO 21501-4 certificate against PSL spheres, issued per unit, and ask what the annual turnaround is before you need it.

7

Sampling Accessories

An isokinetic probe belongs in the box, not on the options list. Add a high-pressure diffuser if you sample compressed gas, and spare inlet filters.

Follow these steps to choose the right handheld particle counter for your cleanroom

Home